4445 S. 74th E. Ave. Tulsa, OK 74145 Phone: 918.627.3188 Fax: 918.627.2676
1415 FM 1960 East Houston, TX 77073 Phone: 281.445.8700 Fax: 281.445.8880
12441 Business Highway 287N Ft. Worth, TX 76179 Phone: 817.230.4249 Fax: 817.350.4537
5116 NW 3rd Street, Oklahoma City, OK 73128 Phone: 405.603.6722 Fax: 405.603.6737
3519 W. Beal City Road, Weidman, MI 48893 Phone: 989.441.1500 Fax: 989.441.1505
9745 E. Hampden Ave., Suite 250 Denver, CO 80231 Phone: 720.833.7032 Fax: 303.344.1525
101 Alexander Avenue Pompton Plains, NJ 07444 Phone: 973.616.4501 Fax: 973.616.4451
7 West End Way Norwell, MA 02061 Phone: 781.261.9688 Fax: 781.261.9679
3180 Industry Drive - Unit "C" North Charleston, SC 29418 Phone: 843.628.1342 Fax: 866.594.3233
3216 Wetmore Ave., Suite 207 Everett, WA 98201 Phone: 425.903.4850 Fax: N/A
206 Eleanor Ct NW, South Prairie, WA 98385 Phone: 425.903.4850 Fax: N/A
6711 NE 58th Ave Vancouver, WA 98661 Phone: 360.694.6242 Fax: 360.737.3766
17902 Georgetown Lane Huntington Beach, CA 92647 Phone: 714.963.6202 Fax: 714.963.6360
14538-121A Avenue Edmonton, AB T5L 4L2 Phone: 780.453.6677 Fax: 780.482.4356
1.888.800.MESA
EnviroCoke IV™ combines the conductive properties of natural round grain Calcined Fluid Petroleum Coke particles with the low permeability properties of grout. The Coke particles are specifically sized to form the main conductive structure of the electrically conductive grout. To enhance the conductivity properties of EnviroCoke IV™, other forms of high quality carbon are added to the composite mixture. Further additives make installation easier by minimizing the apparent viscosity of the slurry. The additives insure the compatibility of EnviroCoke IV™ with equipment normally used to install cathodic protection systems.
EnviroCoke IV™ is designed specifically for use in the discharging zone on the outside of a conductive casing, with anodes and Loresco SC-3® inside the casing. By placing EnviroCoke IV™ around the casing on the outside, a conductive seal is formed which serves as an environmental precaution against interchange flow between water bearing formations in the discharging zones. When used in conjunction with PermaPlug, total environmental control can be established.
EnviroCoke IV™, with its conductivity and ease of installation, provides a solution to environmental concerns pertaining to deep anode installations in sensitive areas.
EnviroCoke IV™ must be pre-mixed thoroughly with water before pumping. Mix 7 gallons of water with each 100 lb. bag of EnviroCoke IV™. Mixing and placement may be undertaken as a single batch process or in a continuous series fashion. Once installation has started, pumping should not be interrupted. EnviroCoke IV™ should be placed by pumping from the bottom of the earth hole up using a minimum 1 inch steel placement pipe. Minimum pumping pressure required in a 300 foot deep system is approximately 125 psi. The casing EnviroCoke IV™ is placed around will be buoyant during installation.
A mud of sufficient weight should be added to the inside of the casing or hold the casing with suitable clamps to prevent floating. EnviroCoke IV™ becomes structurally stable 24 hours following installation. Clamps or mud may be removed at this time.
EnviroCoke IV™ is a seal which will minimize water transfer. A vent pipe for the release of gases and as a facility for water addition is recommended. Loresco's AllVent™ is preferred because of its unique design. It is specifically made for use with the EnviroCoke IV™ system.