Features
· Slim, ergonomic design
· Large, easy to read backlight display
· CAT 1V 300V/CAT III 600 V safety rating
· Hold button
· Two-year warranty
· Soft carrying case
Measurement capability
· 400 A AC and dc current measurement
· 600 V AC and dc voltage measurement
· True-rms AC voltage and current for accurate measurements on no-linear signals
· Resistance measurement up to 40 kΩ with continuity detection
· Temperature and capacitance measurement
· Frequency measurements
Electrical Specifications AC Current (Jaw)
Range
323 ........................................................ 400.0 A
324, 325 ................................................ (40.00, 400.0) A
Resolution
323 ........................................................ 0.1 A
324, 325 ................................................ (0.01, 0.1) A
Accuracy ................................................ 2.0 % + 5 digits (45 – 65 Hz)
2.5 % + digits (65 – 400 Hz)
DC Current with Jaw (325)
Range...................................................... (40.00, 400.0) A
Resolution ............................................... (0.01, 0.1) A
Accuracy ................................................. 2.0 % + 5 digits
AC Voltage
Range....................................................... 600.0 V
Resolution ............................................... 0.1 V
Accuracy (45 – 400 Hz) .......................... 1.5 % + 5 digits
DC Voltage
Range ...................................................... 600.0 V
Resolution ............................................... 0.1 V
Accuracy ................................................. 1 % + 5 digits
Resistance
Range
323, 324 .................................................. (400.0, 4000) Ω
325 .......................................................... (400.0, 4000, 40000) Ω
Resolution ............................................... (0.1, 1, 10) Ω
Accuracy ................................................. 1 % + 5 digits
Continuity Beeper
323 .......................................................... ≤70 Ω
324/325 ................................................... ≤30 Ω
Capacitance (324, 325)
Range ..................................................... (100.0, 1000) μF
Resolution ............................................... (0.1, 1) μF
Accuracy ................................................. 1 % + 4 digits
Frequency (325)
Range ..................................................... 5.0 to 500.0 Hz
Resolution ............................................... 0.1 Hz
Accuracy ................................................. 0.5 % + 4 digits
Trigger Level ........................................... 5 to 10 Hz, ≥10 A
10 to 100 Hz, ≥5 A
100 to 500 Hz, ≥10 A
Contact Temperature (324, 325)
Range...................................................... -10.0 °C to 400.0 °C
Resolution ............................................... 0.1 °C
Accuracy ................................................. 1 % + 8 digits
Note: Temperature uncertainty (accuracy) does not include error of the thermocouple probe.
Mechanical Specifications
Size (L x W x H) ....................................... (207 x 75 x 34) mm
Weight
323 ......................................................... 265 g
324 ......................................................... 208 g
325 ......................................................... 283 g
Environmental Specifications
Operating Temperature ......................... -10 °C to +50 °C
Storage Temp ......................................... -30 °C to +60 °C