The B3A2 was designed specifically as a cathodic protection test instrument. In most cases it is all that is required for the test and evaluation of existing systems or design or new installation. It can be utilized in making the following tests, which are illustrated in the B3A2 operating manual.
· Structure-to-soil potentials. Current measurements (direct null-amp method, 2 or 4 terminal zero resistance).
· IR drops and calibration of IR drop test stations.
· Soil or water resistivity by soil box and by 4-electrode method.
· Soil potential gradients.
· Continuity tests.
· Pipe coating resistance tests and fault surveys (over-the-ground method).
· Galvanic anode rectifier output and cathodic protection interference tests.
· Duct slug survey on lead covered cables and concrete bridge deck surveys.
· pH determination.
· Grounding tests.
Left Meter
· 9 DC voltage ranges, zero to full scale: 2 mV, 10 mV, 20 mV, 100 mV, 200 mV, 1 V, 2 V, 10 V, 100 V.
· Minus 10% of full scale on all ranges.
· Input polarity reversal switch on volts and amps ranges eliminates the need to reverse test leads.
· Best resolution: 20 micro volts (0.00002 V) on the 2 mV range.
· Input Resistance: 10.000 Ω on 2 mV and 10 mV ranges. 10 MΩ on 20 mV to 100 V ranges.
· Life frequency rejection: > 60 db @ 60 Hz.
· RF rejection: > 70 dB @ 1M Hz.
· Overload protection: 10 times full scale.
· 9 DC ampere ranges, zero to full scale: 2 mA, 10 mA, 20 mA, 100 mA, 200 mA, 1 A, 2 A, 10 A, 20 A.
· Minus 10% of full scale on all ranges.
· Best resolution: 20 microamps on the 2mA range.
· Overload allowed: 5 times full scale, less than 5 sec.
· Contact check: >200 mA short circuit.
· Adjustable output current supply: Controllable 0 to 3 VDC and 0 to 4 amps.
· Control external current flow with built-in 25 watts adjustable rheostats.
· Read internal battery voltage directly.
· Left meter switch: Internally connects right meter to left terminals, enabling current and voltage to be read simultaneously.
Right Meter
· 9 DC voltage ranges, zero to fullscale: 2 mV, 10 mV, 20 mV, 100 mV, 200 mV, 1 V, 2 V, 10 V, 20 V.
· Minus 10% of full scale on all ranges.
· Input polarity reversal switch on volts.
· Best resolution: 20 microvolts (0.00002V) on the 2 mV range.
· Input resistance: 100,000 Ω on 2 mV and 10 mV ranges. Selectable from 1 MΩ, 10 MΩ, 25 MΩ, 50 MΩ, 100 MΩ, 200 MΩ on 20 mV to 100 V ranges.
· RF rejection > 70 db @ 1 MHz.
· Bias control + full scale, all ranges.
· Overload protection 10 times full scale.