4445 S. 74th E. Ave. Tulsa, OK 74145 Phone: 918.627.3188 Fax: 918.627.2676
1415 FM 1960 East Houston, TX 77073 Phone: 281.445.8700 Fax: 281.445.8880
12441 Business Highway 287N Ft. Worth, TX 76179 Phone: 817.230.4249 Fax: 817.350.4537
5116 NW 3rd Street, Oklahoma City, OK 73128 Phone: 405.603.6722 Fax: 405.603.6737
3519 W. Beal City Road, Weidman, MI 48893 Phone: 989.441.1500 Fax: 989.441.1505
9745 E. Hampden Ave., Suite 250 Denver, CO 80231 Phone: 720.833.7032 Fax: 303.344.1525
101 Alexander Avenue Pompton Plains, NJ 07444 Phone: 973.616.4501 Fax: 973.616.4451
7 West End Way Norwell, MA 02061 Phone: 781.261.9688 Fax: 781.261.9679
3180 Industry Drive - Unit "C" North Charleston, SC 29418 Phone: 843.628.1342 Fax: 866.594.3233
3216 Wetmore Ave., Suite 207 Everett, WA 98201 Phone: 425.903.4850 Fax: N/A
206 Eleanor Ct NW, South Prairie, WA 98385 Phone: 425.903.4850 Fax: N/A
6711 NE 58th Ave Vancouver, WA 98661 Phone: 360.694.6242 Fax: 360.737.3766
17902 Georgetown Lane Huntington Beach, CA 92647 Phone: 714.963.6202 Fax: 714.963.6360
14538-121A Avenue Edmonton, AB T5L 4L2 Phone: 780.453.6677 Fax: 780.482.4356
1.888.800.MESA
Tinker & Rasor's Model PD and the Null Method have been recognized as being the fastest method to accurately locate points of electrical contact and insulating joints on coated underground piping stems. The Tinker & Rasor Model PD is unaffected by parallel lines, depths, 60 Hz or ground cover, the survey can often be, in part, conducted from a moving vehicle over the pipe. In brief, the Null Method follows the flow of impressed audio frequency current in a coated pipe; determines where it leaves. This method is quite and accurately. The Model PD is also an excellent device for pinpointing defects in coatings on buried pipelines. This unit is also highly accurate in locating breaks in cables such as anode leads on impressed current, cathodic protection systems.
You should be aware that we have made a few changes to the Model PD recently (08-30-04):
· The Oscillator (PD-C) has been updated to include LED lights instead of the meter, and the Output Indicator light has been replaced with a Fine Adjust knob.
· The crystal in the Oscillator (PD-C) has been changed. There is a noticeable difference in the interrupt cycle rate from previous versions. The cycle is much faster now. This is an engineering change and not a problem with the instrument.
· The Model PD Complete Holiday Detector Kit comes with connector cables to use between operators when conducting a Pearson Method Holiday Detector survey. The length of cable between operators has been shortened from 30' to 20'.
· Mark IV Receiver with battery.
· PD-C Oscillator.
· Battery Cables (set).
· 30' Black Ground Cable.
· Carrying Case.
· The 45/90 Probe with telescopic handle sold separately.
PD Pearson type Holiday Detector Components include:
· Shoe Cleats (set of 4)
· Terminal Board (single connection)
· Terminal Board (double connection)
· 30' Connecting Cable
· Cleat Cables (set of 4)
· Shipping weight: 28 lb