4445 S. 74th E. Ave. Tulsa, OK 74145 Phone: 918.627.3188 Fax: 918.627.2676
1415 FM 1960 East Houston, TX 77073 Phone: 281.445.8700 Fax: 281.445.8880
12441 Business Highway 287N Ft. Worth, TX 76179 Phone: 817.230.4249 Fax: 817.350.4537
5116 NW 3rd Street, Oklahoma City, OK 73128 Phone: 405.603.6722 Fax: 405.603.6737
3519 W. Beal City Road, Weidman, MI 48893 Phone: 989.441.1500 Fax: 989.441.1505
9745 E. Hampden Ave., Suite 250 Denver, CO 80231 Phone: 720.833.7032 Fax: 303.344.1525
101 Alexander Avenue Pompton Plains, NJ 07444 Phone: 973.616.4501 Fax: 973.616.4451
7 West End Way Norwell, MA 02061 Phone: 781.261.9688 Fax: 781.261.9679
3180 Industry Drive - Unit "C" North Charleston, SC 29418 Phone: 843.628.1342 Fax: 866.594.3233
3216 Wetmore Ave., Suite 207 Everett, WA 98201 Phone: 425.903.4850 Fax: N/A
206 Eleanor Ct NW, South Prairie, WA 98385 Phone: 425.903.4850 Fax: N/A
6711 NE 58th Ave Vancouver, WA 98661 Phone: 360.694.6242 Fax: 360.737.3766
17902 Georgetown Lane Huntington Beach, CA 92647 Phone: 714.963.6202 Fax: 714.963.6360
14538-121A Avenue Edmonton, AB T5L 4L2 Phone: 780.453.6677 Fax: 780.482.4356
1.888.800.MESA
The Model 54-A soil resistivity apparatus is lightweight, accurate and simple to operate. It lends itself equally well to spot checks of soil or water resistivity, or to detailed investigation typical of pipeline survey work.
The complete apparatus consists of a 40" calibrated hexagonal steel rod with handles and insulated tip, a compact AC resistivity bridge in a leather carrying case, and an ear set for balancing a bridge by null method. The rod is simply pushed into soil to the desired depth and connected to bridge. AC resistance between the tip and body of rod is determined by balancing bridge and soil resistivities in Ohms-cc read direct on the dial.
The soil rod is made of cold drawn hexagonal steel with a hardened steel tip insulated by a nylon washer. The Connecting lead from the tip is brought up through the body of the rod. Units are furnished complete with soil bridge, rod, case, ear set, connecting leads, and instructions.
The bridge weighs only 1 3/4 pounds and is neatly assembled in a 6" x 3" x 2 1/2" polished ebony Bakelite case. The rod is lightweight yet rugged for field usage. It may be used with any standard resistivity bridge and is also very useful as a pipe locating and contact bar for taking pipe potential measurements and long line currents.
Features:
· Range: 0-250,000 Ohms-cc
· 40" rod-standard (50",60", 72" optional)
· Field calibration check
· Pinpoint tuning
· Operates on 9 volt battery
Operating Instructions:
· With soil rod inserted in soil to be tested, connect leads to soil rod and binding posts on Model 54-A marked"LEADS" (#1). Plug ear set into jack marked "PHONES" (#2), flip toggle switch (#3) to "ON" position, bring tone to"NULL" by means of dial pointer (#4). The resistance of the soil will be the dial reading in Ohms per cc.
Test Functions:
· Disconnect leads from soil rod.
· Turn power switch (#3) to "ON".
· Push and hold test switch (#5)"UP".
· While holding, move dial pointer (#4) until tone "NULLS". Reading on dial should match test position value, if not, reset pointer.
· Push and hold test switch (#5) "DOWN".
· Repeat step #4. It is best to check the MODEL 54-A at both points.
· Dimensions: 6 x 3 x 2-1/2 in
· Weight: 1-3/4 lb
· Rod Size:
o 40 in
o 50 in
o 60 in
o 72 in