Electrostop Monolithic Isolation Fittings

The ElectroStop® monolithic isolation fittings serve as a positive leakproof, long lasting block against the flow of electric current in all piping systems. When the ElectroStop® isolation fitting is buried, you bury maintenance costs forever - an especially important feature for system operators and engineers.

The ElectroStop® eliminates short circuits, field assembly and is less expensive than a jointed flange with isolation gaskets.  The ElectroStop® is coated internally and externally to prevent corrosion and is 100% hydrostatically, electrically and weld tested.  All ElectroStop® monolithic isolation joints are manufactured in accordance with ISO 9001-2008.

Standard Tests Include:

  • 100% Hydrostatic Pressure and Electrical Tests
  • 100% Ultrasonic of Welds
  • 100% Magnetic Particle of Welds
  • 100% Dye Penetrant of Welds

BENEFITS/FEATURES

  • Eliminates short circuits.
  • Eliminates field assembly.
  • Eliminates maintenance.
  • Is less expensive.
  • Is coated both internally and externally.
  • Is 100% electrically tested.
  • Is completely weld inspected.
  • Is manufactured in accordance with ISO9001:2000 specifications.
  • 100% butt weld construction

Design Features

  • A low uniform profile enhances ease of handling and field coating or tape wrapping.
  • Fittings can be welded into the pipeline above grade, utilizing standard pipeline welding procedures, then lowered into the trench by a sling.
  • There is a natural heat sink to dissipate circumferential weld heat during installation.   They are tamper proof and maintenance free after installation.  Each fitting follows minimum length which includes the insulating mechanism and pipe pups.  Literature contains more sizing information.
  • The minimum bore of each fitting is equal to the standard bore tolerances of the pipe in which it will be installed.
  • Each fitting uses a method of closure that will positively maintain a pre-stressed load on the insulation section that is in excess of the end loading forces at test pressure.  This is accomplished by weld closure.
  • The insulating member is fiberglass reinforced thermosetting epoxy resin. The sealing gasket is Butadiene/Acrylonitrile rubber conforming to ASTM D2000.

ElectroStop™ isolation fittings provide permanent electrical isolation of piping sections, facilitating the management of a cathodic protection system.  These fittings are completely factory assembled.

Monolithic isolation fittings are boltless and completely factory assembled in accordance with the appropriate requirements of ASTM, API, DIN and BS codes.  All welds are butt weld construction. The dielectric isolation material is a thermosetting fiberglass epoxy material.  Sealing is by two (2) static, self-energized O ring seals housed in accurately machined grooves, fully protected from cavitation in full compliance with ASME design codes. Interior and exterior coating is a two part epoxy with a thickness of 12 to 15 mils to within 2” of each end.  Testing is Electrical (@5kv, 25 Mohm), Hydraulic (@ 1.5 x O.P.) and Weld (Ultrasonic/Magnetic Particle/Dye Penetrant).

Quality Assurance:  Each monolithic isolation fitting is manufactured at a facility that has a Registered ISO 9001:2000 Quality Management System. Copy of current ISO 9001:2000 Registration is provided with material submittal.

150# ANSI CLASS (PN or DP 25)

  • 150# ANSI Pressure Rating = 285 psi
  • ElectroStop Continuous Operating Pressure = 355 psi
  • Test Pressure = 540 psi
  • Working Temperature: Range = 14° F. to 212° F. (-10° C. to 100° C.)
  • Electrical Resistance (Dry Air) = 25 Mohms @ 1kv D.C.
  • Breakdown Voltage (Dry Air) = 5kv @ 50Hz for 1 minute.

* See Note.


300-400# ANSI CLASS (PN or DP 64)
  • 300# ANSI Pressure Rating = 740 psi
  • 400# ANSI Pressure Rating = 990 psi
  • ElectroStop Continuous Operating Pressure = 990 psi
  • Test Pressure = 1,500 psi
  • Working Temperature: Range = 14° F. to 212° F. (-10° C. to 100° C.)
  • Electrical Resistance (Dry Air) = 25 Mohms @ 1kv D.C.
  • Breakdown Voltage (Dry Air) = 5kv @ 50Hz for 1 minute.

* See Note.


600# ANSI CLASS (PN or DP 100)
  • 600# ANSI Pressure Rating = 1,480 psi
  • ElectroStop Continuous Operating Pressure = 1,480 psi
  • Test Pressure = 2,225 psi
  • Working Temperature Range = 14° F. to 212° F. (-10° C. to 100° C.)
  • Electrical Resistance (Dry Air) = 25 Mohms @ 1kv D.C.
  • Breakdown Voltage (Dry Air) = 5kv @ 50Hz for 1 minute.

Note: All data supplied is for standard fittings.  Please contact factory for nominal diameters, pressures (up to 2500 ANSI), temperatures (up to 160° C, 320° F.) and electrical characteristics not shown. The information is subject to change at the manufacturer's discretion.

Sizes

  • Available in any diameter.
  • Available in any ANSI

Warranty

All products are warranted against failure caused by manufacturing defects for a period of one year. Any product found to be so defective and returned within one year from date of shipment will be replaced without charge. The above warranty is made in lieu of, and we disclaim, any and all other warranties, expressed or implied, including the warranties of merchant ability and fitness for a particular purpose, and buyer agrees to accept the products without any such warranties.  We hereby disclaim any obligation or liability for consequential damages, labor costs or any other claims or liabilities of any kind whatsoever.

The ElectroStop™ is a complete factory assembled and tested monolithic isolation fitting which will serve as a leak proof, long lasting block against the flow of electrical current in steel piping systems. Care should be used during the handling and installation process so as not to damage the fitting.

Only two (2) welds are required for installation.

The ElectroStop™ may be installed either above grade or buried below grade.

Note:   WHEN INSTALLING IN A VERTICAL POSITION ABOVE GRADE, THE WELDED END OF THE COLLAR (HUB) SHOULD FACE UP.

The end filled with the epoxy fill (opposite end of the welded collar of hub) can have a concave area and possibly retain moisture and can be sensitive to ultra violet light exposure.

THE SUGGESTIONS BELOW SHOULD NOT PRECLUDE FOLLOWING OF ALL COMPANY, LOCAL, STATE, OR FEDERAL CODES AND/OR SAFETY REQUIREMENTS AND/OR REGULATIONS. DESIGN CONCERNS, INCLUDING ELECTRICAL SAFETY PRECAUTIONS, GROUNDING, MECHANICAL STRESSES, ETC. SHOULD BE ADDRESSED PRIOR TO USE OR INSTALLATION. ALWAYS WEAR PROPER SAFETY EQUIPMENT FOR PERSONAL PROTECTION.  CONSULT WITH YOUR COMPANY.

The ElectroStop™ fitting should be installed just like any other weld-in fitting or piece of pipe with the only exceptions being:

  • The temperature of the collar (hub) should not exceed 212 degrees Fahrenheit (100 degrees Celsius).
  • Piping being attached to the ElectroStop™ must be properly aligned so as not to put undo mechanical stresses on the ElectroStop™.

The pipe pups on the ElectroStop™ are intended to act somewhat as a heat sink and should not be shortened.  If the fitting is too long for the installation location, cut the needed length out of the existing piping, not the ElectroStop®.

During the welding operation a temperature sensor such as a thermometer or thermocouple should be secured to the collar (hub) of the ElectroStop™.  As a precautionary procedure, wet rags or other cooling methods are sometimes used to reduce heat at the collar (hub) area.

COATING
After the welding operation is completed, The ElectroStop™ fitting and welds should be prepared for your corrosion protection coating or tape just like any other bare or shop coated fitting or piece of pipe.

SUPPORT AND BACKFILLING
Care should be used to assure uniform support and compaction around the entire ElectroStop™ fitting. Undo mechanical stresses caused by improper support or backfilling could cause damage to the ElectroStop™ that could result in leakage.

TESTING AND CERTIFICATION
All ElectroStop™ fittings undergo a weld inspection with combinations of ultrasonic (UT), magnetic particle (MT) and dye penetrant (LT) on all welds.  X-Ray tests are preformed upon request.

We certify that each standard order ElectroStop™ will be factory tested at 1-1/2 times the rated operating pressure for the amount of time listed below and in accordance to the latest ANSI Standards.

Pipe Size

Hydrostatic Minimum Test Time

Up to 3"

15 minutes

4"

30 minutes

6" - 8"

1 hour

10" - 16"

2 hours

20" - 24"

12 hours

Above 24"

As required by each specification.

After completion of the hydrostatic tests, The ElectroStop™ are electrically tested to assure an electrical resistance of 25 Mohms (wet or dry conditions @ 20( C) @ 1kv D.C. and a minimum breakdown voltage of 5kv @ 50 hz for 1 minute.

Control over all stages of production is ensured by close adhearance to an in-place and ongoing ISO 9001 Quality Assurance Program which is constantly monitored and subject to periodic outside audit.  A qualified inspector witnesses all tests.

How To Order

To order ElectroStop™ Monolithic Isolating Fittings please indicate the following:

1.     Quantity

2.     Nominal Pipe Size

3.     ANSI, DIN, API Pressure Class or Actual Working Pressure

4.     Pipe Grade

5.     Wall Thickness

6.     Temperature Limits

7.     Product Conveyed

8.     Contact your local distributor or GPT.

Product(s)

Item #Product NameQuoteSpecs
Electrostop Monolithic Isolation Fittings Electrostop Monolithic Isolation Fittings PDF

Related Products

Have a Question?
Name:*
Email:*
Phone:
Question:*
Security Code: