206 Eleanor Ct NW, South Prairie, WA 98385 Phone: 425.903.4850 Fax: N/A
6711 NE 58th Ave Vancouver, WA 98661 Phone: 360.694.6242 Fax: 360.737.3766
17902 Georgetown Lane Huntington Beach, CA 92647 Phone: 714.963.6202 Fax: 714.963.6360
14538-121A Avenue Edmonton, AB T5L 4L2 Phone: 780.453.6677 Fax: 780.482.4356
1.888.800.MESA
Stelth 2 Reference Electrodes (Underground and Concrete)
Stationary Reference Electrodes for Underground and Concrete
· Minimum 20 year service life.
· 28 square inches of sensing surface area gives 9 to 35 times more surface areas than other electrodes. This makes electrode positioning less critical to achieve accurate readings.
· Will not dry out in desert dry soil, a condition that renders other electrodes ineffective. Cyclical variations in soil conditions, ranging from hydrated to dehydrated, have adverse effect on the Stelth 2 electrode.
· Will not be destroyed by absolute dry soil conditions. It will only lie dormant until moisture returns. Electric Mud™ backfill will keep Stelth 2 in a moisture environment which keeps it continuously active.
· Electrode may be taken out of service for extended periods of time and reintroduced into the system without affecting electrode accuracy or ability to reactivate. Electrode will fire up in under 5 minutes.
· Technologically advanced chloride ion trap prevents chloride contamination of electrolyte.
· Available in three models: CuCuSO4, AgAgCL, ZnZnSO4.
· Color coding matches industry standards. Electrode and wire are both color coded for quick and easy remote identification of electrode chemistry.
· Fully compatible in a gelatin backfill environment such as Electric Mud™.
· Complete installation instructions included.
SRE-007-CUY
Copper-Copper Sulfate Electrode (Cu-CuSO4) for Underground and Concrete Service
SRE-008-SUB
Silver-Silver Chloride Electrode (Ag-AgCL) for High Chloride Underground and Concrete Service
SRE-006-ZUR
Zinc-Zinc Sulfate Electrode (Zn-ZnSO4) for Underground and Concrete Service
Diameter
1.5 in
Length
6 in
Case Color
Yellow
Blue
Red
Case Material
Ceramic
Wire Size
20 ft Standard (Contact Mesa for other lengths)
Wire Type
14 RHH-RHW
Wire Color
Service Life
20 years
Stability
10 millivolts with 3 microamp load
Temperature Range
+32 to +135°F
+32 to +150°F