4445 S. 74th E. Ave. Tulsa, OK 74145 Phone: 918.627.3188 Fax: 918.627.2676
1415 FM 1960 East Houston, TX 77073 Phone: 281.445.8700 Fax: 281.445.8880
12441 Business Highway 287N Ft. Worth, TX 76179 Phone: 817.230.4249 Fax: 817.350.4537
5116 NW 3rd Street, Oklahoma City, OK 73128 Phone: 405.603.6722 Fax: 405.603.6737
3519 W. Beal City Road, Weidman, MI 48893 Phone: 989.441.1500 Fax: 989.441.1505
9745 E. Hampden Ave., Suite 250 Denver, CO 80231 Phone: 720.833.7032 Fax: 303.344.1525
101 Alexander Avenue Pompton Plains, NJ 07444 Phone: 973.616.4501 Fax: 973.616.4451
7 West End Way Norwell, MA 02061 Phone: 781.261.9688 Fax: 781.261.9679
3180 Industry Drive - Unit "C" North Charleston, SC 29418 Phone: 843.628.1342 Fax: 866.594.3233
3216 Wetmore Ave., Suite 207 Everett, WA 98201 Phone: 425.903.4850 Fax: N/A
206 Eleanor Ct NW, South Prairie, WA 98385 Phone: 425.903.4850 Fax: N/A
6711 NE 58th Ave Vancouver, WA 98661 Phone: 360.694.6242 Fax: 360.737.3766
17902 Georgetown Lane Huntington Beach, CA 92647 Phone: 714.963.6202 Fax: 714.963.6360
14538-121A Avenue Edmonton, AB T5L 4L2 Phone: 780.453.6677 Fax: 780.482.4356
1.888.800.MESA
Built strictly to the DIN Standard 50925 – European and U.S. patents applied for.
Stelth 7 IR Free Stationary Reference Probe
(Includes Bullet™ Box IR Free Interrupter; Bullet™ Box CP Test Station)
SRE-022-CIY – *1 cm² SRE-023-CIY - *10 cm² SRE-024-CIY *100 cm²
Copper-Copper Sulfate Electrode (Cu-CuSO4) IR Free Stationary Reference Probe
*Coupon
SRE-025-SIB – *1 cm² SRE-026-SIB - *10 cm² SRE-027-SIB - *100 cm²
Silver-Silver Chloride Electrode (Ag-AgCL) IR Free Stationary Reference Probe
SRE-028-ZIR – *1 cm² SRE-029-ZIR - *10 cm² SRE-030-ZIR – 100 cm²
Zinc-Zinc Sulfate Electrode (Zn-ZnSO4) IR Free Stationary Reference Probe
Stability
10 millivolts with 3 microamp load
Service Life
20 years
Temperature Range
+32 to + 135°F
+32 to +135°F
Stelth 7 Rocket IR-Free Stationary Reference Probe
SRE-031-CIY 50 or 100 cm² Coupon
SRE-032-SIB 50 or 100 cm² Coupon
SRE-033-ZIR 50 or 100 cm² Coupon
· An IR Free Potential is a potential measured at the exact point where the surface of the structure meets the surrounding environment. A potential measurement at this point is not distorted by the soil resistance between reference electrode and the structure's surface.
· The "Stelth 7" IR-Free reference probe is designed to provide is designed to provide an IR Free Potential reading that is as close as theoretically possible to that point where the structure and environment meet. This is achieved by combining into a "PROBE" the proven Stelth technology and a precision mild steel coupon which, when placed in the same soil conditions as the structure, will be exposed to the identical forces acting upon this structure's flaws or holidays (exposed areas) such as the cathodic protection system, stray currents and environmental conditions.
Use
· How to set-up and measure with the "Stelth 7" Probe: The "Stelth 7" probe is connected to your structure through a test station. Two wires are connected to the structure and are brought into the test station. Two wires are connected to the structure and are brought into the test station and connected to terminals four and five. Two wires connected to the steel coupon in the probe are brought into the test station and connected to terminals one and two. The third wire connected to the reference electrode in the probe is brought into the test station and connected to terminal three. A shunt is placed across terminals one and four. Your potential reading is taken across terminals two and three.