4445 S. 74th E. Ave. Tulsa, OK 74145 Phone: 918.627.3188 Fax: 918.627.2676
1415 FM 1960 East Houston, TX 77073 Phone: 281.445.8700 Fax: 281.445.8880
12441 Business Highway 287N Ft. Worth, TX 76179 Phone: 817.230.4249 Fax: 817.350.4537
5116 NW 3rd Street, Oklahoma City, OK 73128 Phone: 405.603.6722 Fax: 405.603.6737
3519 W. Beal City Road, Weidman, MI 48893 Phone: 989.441.1500 Fax: 989.441.1505
9745 E. Hampden Ave., Suite 250 Denver, CO 80231 Phone: 720.833.7032 Fax: 303.344.1525
101 Alexander Avenue Pompton Plains, NJ 07444 Phone: 973.616.4501 Fax: 973.616.4451
7 West End Way Norwell, MA 02061 Phone: 781.261.9688 Fax: 781.261.9679
3180 Industry Drive - Unit "C" North Charleston, SC 29418 Phone: 843.628.1342 Fax: 866.594.3233
3216 Wetmore Ave., Suite 207 Everett, WA 98201 Phone: 425.903.4850 Fax: N/A
206 Eleanor Ct NW, South Prairie, WA 98385 Phone: 425.903.4850 Fax: N/A
6711 NE 58th Ave Vancouver, WA 98661 Phone: 360.694.6242 Fax: 360.737.3766
17902 Georgetown Lane Huntington Beach, CA 92647 Phone: 714.963.6202 Fax: 714.963.6360
14538-121A Avenue Edmonton, AB T5L 4L2 Phone: 780.453.6677 Fax: 780.482.4356
1.888.800.MESA
· These electrodes are buried directly with native soil backfill – no need for composite backfills. These products are suitable for use in neutral soil having a chloride ion content <500ppm. (AccuRef Silver/Silver Chloride electrodes are recommended for use in higher chloride ion content soils.)
· Depressed electrolyte freezing temperature of -20°C allows electrodes to experience a deep frost without freezing and cracking.
· Large electrical contact area (electrically active surface area) having hygroscopic characteristics promotes good electrode-to-soil electrical contact. (Note: Soil moisture content is a requirement for a buried metallic structure potential reading versus any permanently installed reference electrode, which means that readings in ultra-dry soil are not possible.)
Features:
· Electrode: Permanent Copper/CopperSulfate
· Applications: Direct burial in soil, assuming low (<500ppm) levels of chloride ion contamination.
· Low Freezing Point: -20°C.
· Design Life: 30 years.
· High Purity: CuCuSO4 and triple de-ionized H20.
· Cost: Less expensive than most Copper Sulfate permanent electrodes.
· Tip: Moisture absorbent ceramic tip.
· Evaporation: Will not dry out in low humidity and/or high heat.
· Wire: 25 feet of AWG 12 lead wire; cross-linked Polyethylene jacket, direct burial, low leakage, 600V, 90°C. Rating, Use-12/RHH/RHW-2. Longer lengths of wire are available.
· Electrical Contact Surface Area: Approx. 16.4 square inches (a cylindrical surface, 1.5 inches in diameter and 3.5 inches in length).