Air Cooled Standard Line Rectifier

The "Standard Line" air cooled, cathodic protection rectifiers are recognized as industry leading in quality, workmanship and service life.  Many years of field-proven service prove their superior design.  Conservative equipment ratings, controlled manufacturing techniques, plus many extra features ensure long and trouble-free operation.

Typical cathodic protection applications for the air cooled rectifier line include pipelines, tank farms, storage fields, and other non-hazardous locations where continuous duty, DC power is required.

Standard Features:

·       Weatherproof to NEMA 3R.

·       Heavy duty 11-gauge hot dip galvanized cabinet with Stainless Steel Hardware.

·       Stainless Steel, perforated screens.

·       Front and side opening doors for easy maintenance.

·       Heavy duty, draw-pull, stainless steel cabinet latch.

·       Slide-out equipment racks, separate Transformer and Stack assemblies for units over 1200 watts.

·       Heavy duty transformer with 15% over-design for reserve capacity.

·       Minimum 18-step voltage control link bar taps.

·       Quick-change, heavy-duty knobs for changing tap link bars.

·       Minimum 5/16" diameter, soldered tap changing studs.

·       3/16" Grade XX, Phenolic front panel.

·       Accessible front panel total precision shunt.

·       Magnetic AC input circuit breaker.

·       Magnetic AC Secondary Breakers on all units less than 100 amps (instead of fuses).

·       Hoyt, separate analog, 2-1/2"round, volt and amp meters.

·       Silicon diodes protected by surge suppressors and current limiting breakers <100 Amps or fuses.

·       All electrical connection hardware is Nickel Plated and double-nut or soldered.

·       Multi-strand, high temperature, insulated flexible wiring.

·       Terminal block for AC input wires.

·       Primary tap change panel for dual input voltages (Single Phase models only).

·       Safety shield panel supplied on all units over 65 Volts DC.

Ordering Code / Model Number, Air Cooled Standard Line

Position #1: MODEL

A = Air Cooled Line, Air Cooled

Position #2: TYPE

S = Standard Rectifier (Manual taps)

P = Constant Potential (solid state)

C = Constant Current (Reactor style)

I = Constant Potential IR free (solid state)

D = Constant Current (Solid state)

M = Multiple Modes (Specify Modes Required)

E = Constant Voltage (Solid state)

V = Variac Control

Position #3: COOLING

A = Air Cooled

Position #4: STACK TYPE

I = Silicon (recommended); E = Selenium

 

Position #5: DC VOLTS

List Maximum DC Voltage Desired

Position #6: DC AMPS

List Maximum DC Amperage Desired

Position #7: AC INPUT

AA = 115/230, 1 phase set for 115 vac

AB = 115/230, 1 phase set for 230 vac

BA = 230/460, 1 phase set for 230 vac

BB = 230/460, 1 phase set for 460 vac

CA = 230/460, 3 phase set for 230 vac

CB = 230/460, 3 phase set for 460 vac

EA = 115/460, 1 phase set for 115 vac

EB = 115/460, 1 phase set for 460 vac

G = 115, 1 phase only

D = 208, 3 phase

H = 230, 1 phase only

F = Specify

Position #8: SPECIAL FEATURES

C = AC and DC arrestors

R = 115 VAC convenience outlet

D = DC arrestor

N = Powder coated cabinet (hot-dip galvanized standard on most models)

E = AC arrestor

O = Aluminum cabinet

F = Filter choke

T = Anodized aluminum cabinet

G = Communications filter

U = Anodized aluminum with clear coat

H = Meter switches

P = Additional voltage control link bar taps

I = Base mounting

S = Multiple rectifiers in one case (qty.)

J = Power On indicator light

Q = Other, specify ETL Certified

K = DC failure warning light

 

M = DC breaker (> 100 amps) or fuse

 