Trenton Innercoat for Flange Fill

Innercoat is used in a vertical flange fill.

1.     Heat Innercoat® in pail to 200°F using a thermometer to monitor temperature.  Once temperature is achieved, reduce heat and maintain temperature.

2.     Wrap flange gap with duct tape (two wraps).  Make a hole in the top for inserting the funnel.

3.     Pour Innercoat through the funnel slowly and continuously until the Innercoat has fully filled the flange gap.  The level of Innercoat will decrease as it fills the voids in the flange.  Continue to top-off flange gap until the level of Innercoat no longer decreases.

4.     After the flange gap has been completely filled, allow 20 to 30 minutes cooling time and remove the duct tape.

5.     If an outerwrap is desired after removal of the duct tape, use Trenton #1 Wax-Tape® (for below ground) #2Wax-Tape® (for above and below ground) to protect the outside flange bolts and to interface with the Innercoat wax at the flange gap seam.

 

Packaging

· 47 lb box

· 7 ½ lb blocks (10 per case)

· 7 ½ lb blocks (quartered) (10 per case)

Specifications:

Color

Brown

Specific gravity at 77°F

550°F

Flash Point

350°F minimum

Melting Point

160° - 175°F

Penetration at 77°F

26 - 50

Dielectric Strength

100 volts/mil

Product(s)

Item #Product NameQuoteSpecs
Innercoat for Flange Fill Innercoat for Flange Fill PDF

Related Products

Have a Question?
Name:*
Email:*
Phone:
Question:*
Security Code: