Oil Cooled Standard Universal Rectifiers

Heavy-duty, rugged rectifiers for operation under severe conditions

The oil cooled cathodic protection rectifiers are recognized as industry leading in quality, workmanship and service life. Many years of field-proven service have led to the superior design of these rectifiers. Conservative equipment ratings, controlled manufacturing techniques, plus many extra features ensure long and trouble-free operation.

Typical cathodic protection applications for the oil cooled rectifier line include severe environmental conditions due to humidity, dust, or other situations that would shorten the life of a standard air cooled rectifier.

Hazardous location models are used for Class 1, Div-2, Group D locations and comply with U.L. Standard 698. While similar to the standard oil cooled rectifiers, the explosion proof units are fitted with special hazardous area fittings to eliminate possibility of an ignition source.

Standard Features Oil Cooled:

·       Heavy duty 11 gauge hot dip galvanized cabinet with hinged top lid and stainless steel hardware.

·       External cabinet fins for added strength and cooling.

·       Heavy duty, draw-pull, stainless steel cabinet latches.

·       Separate instrument compartment with hinged door and stainless steel hardware.

·       Separate lift-out component racks for the transformer and rectifier and rectifier stack.

·       Heavy duty transformer with 15% over design for reserve capacity.

·       Minimum 18-step voltage control linkbar taps.

·       Quick-change heavy duty knobs for changing tap link bars.

·       Minimum 5/16" diameter, solder tap changing studs.

·       3/16" Grade XX, Phenolic panels.

·       AC input circuit breaker.

·       Magnetic AC secondary circuit breakers on all units less than 100 amps (instead of fuses).

·       Hoyt, separate analog, 2-1/2" round, volt and amp meters.

·       Silicon diodes protected by surge suppressors and current limiting breakers <100 Amps or fuses.

·       All electrical connection hardware is Nickel Plated and double-nut or soldered.

·       Multi-strand, high temperature, insulated flexible wiring.

·       Terminal block for AC input wires (Non-Hazardous models only).

Optional Features for Oil Cooled Rectifiers:

·       Variety of AC voltage inputs, Single Phase, Three Phase, 50 or 60 Hertz.

·       AC and/or DC High Energy lightning protection.

·       Efficiency filter chokes.

·       Communications filters.

·       Meter switches.

·       Power-on indicator light.

·       DC failure warning lights.

·       DC circuit breakers <100 amps or fuses.

·       115 VAC convenience outlet.

·       Optional cabinet materials, such as stainless steel.

·       Additional voltage control link barstaps.

·       Alternate output control (constant current, constant voltage, constant potential, and constant potential with IR drop free feature.

·       Powder coated cabinet finishes over galvanized coating (white or gray standard).

·       Other options per request from customer.

Ordering Code / Model Number: Oil Cooled

Position #1: MODEL

O = Standard Line, Oil cooled

Position #2: TYPE

S = Standard Rectifier (Manual taps)

P = Constant Potential (solid state)

C = Constant Current (Reactor style)

I = Constant Potential IR free (solid state)

D = Constant Current (Solid state)

M = Multiple Modes (Specify Modes Required)

E = Constant Voltage (Solid state)

V = Variac Control

Position #3: COOLING

O = Oil Cooled Standard

X = Oil Cooled (Hazardous Location) Class 1, Div. 2

Position #4: STACK TYPE

I = Silicon (recommended)

E = Selenium

Position #5: DC VOLTS

List Maximum DC Voltage Desired

Position #6: DC AMPS

List Maximum DC Amperage Desired

Position #7: AC INPUT

AA = 115/230, 1 phase set for 115 vac

AB = 115/230, 1 phase set for 230 vac

BA = 230/460, 1 phase set for 230 vac

BB = 230/460, 1 phase set for 460 vac

CA = 230/460, 3 phase set for 230 vac

CB = 230/460, 3 phase set for 460 vac

EA = 115/460, 1 phase set for 115 vac

EB = 115/460, 1 phase set for 460 vac

G = 115, 1 phase only

D = 208, 3 phase

H = 230, 1 phase only

F = Specify

Position #8: SPECIAL FEATURES

C = AC and DC arrestors

K = DC failure warning light

D = DC arrestor

M = DC breaker (> 100 amps) or fuse

E = AC arrestor

R = 115 VAC convenience outlet*

F = Filter choke

P = Additional voltage control link bar taps

G = Communications filter

S = Multiple rectifiers in one case (qty.)

H = Meter switches*

Q = Other, specify

J = Power On indicator light

*= For Standard Oil Cooled Rectifiers Only

Product(s)

Item #Product NameQuoteSpecs
Oil Cooled Rectifiers Oil Cooled Rectifiers PDF

Related Products

Have a Question?
Name:*
Email:*
Phone:
Question:*
Security Code: