Air Cooled Standard Line Rectifier

Air Cooled Standard Line Rectifier

The "Standard Line" air cooled, cathodic protection rectifiers are recognized as industry leading in quality, workmanship and service life.  Many years of field-proven service prove their superior design.  Conservative equipment ratings, controlled manufacturing techniques, plus many extra features ensure long and trouble-free operation.

Typical cathodic protection applications for the air cooled rectifier line include pipelines, tank farms, storage fields, and other non-hazardous locations where continuous duty, DC power is required.

Standard Features:

·       Weatherproof to NEMA 3R.

·       Heavy duty 11-gauge hot dip galvanized cabinet with Stainless Steel Hardware.

·       Stainless Steel, perforated screens.

·       Front and side opening doors for easy maintenance.

·       Heavy duty, draw-pull, stainless steel cabinet latch.

·       Slide-out equipment racks, separate Transformer and Stack assemblies for units over 1200 watts.

·       Heavy duty transformer with 15% over-design for reserve capacity.

·       Minimum 18-step voltage control link bar taps.

·       Quick-change, heavy-duty knobs for changing tap link bars.

·       Minimum 5/16" diameter, soldered tap changing studs.

·       3/16" Grade XX, Phenolic front panel.

·       Accessible front panel total precision shunt.

·       Magnetic AC input circuit breaker.

·       Magnetic AC Secondary Breakers on all units less than 100 amps (instead of fuses).

·       Hoyt, separate analog, 2-1/2"round, volt and amp meters.

·       Silicon diodes protected by surge suppressors and current limiting breakers <100 Amps or fuses.

·       All electrical connection hardware is Nickel Plated and double-nut or soldered.

·       Multi-strand, high temperature, insulated flexible wiring.

·       Terminal block for AC input wires.

·       Primary tap change panel for dual input voltages (Single Phase models only).

·       Safety shield panel supplied on all units over 65 Volts DC.

Ordering Code / Model Number, Air Cooled Standard Line

Position #1: MODEL

A = Air Cooled Line, Air Cooled

Position #2: TYPE

S = Standard Rectifier (Manual taps)

P = Constant Potential (solid state)

C = Constant Current (Reactor style)

I = Constant Potential IR free (solid state)

D = Constant Current (Solid state)

M = Multiple Modes (Specify Modes Required)

E = Constant Voltage (Solid state)

V = Variac Control

Position #3: COOLING

A = Air Cooled

Position #4: STACK TYPE

I = Silicon (recommended); E = Selenium

 

Position #5: DC VOLTS

List Maximum DC Voltage Desired

Position #6: DC AMPS

List Maximum DC Amperage Desired

Position #7: AC INPUT

AA = 115/230, 1 phase set for 115 vac

AB = 115/230, 1 phase set for 230 vac

BA = 230/460, 1 phase set for 230 vac

BB = 230/460, 1 phase set for 460 vac

CA = 230/460, 3 phase set for 230 vac

CB = 230/460, 3 phase set for 460 vac

EA = 115/460, 1 phase set for 115 vac

EB = 115/460, 1 phase set for 460 vac

G = 115, 1 phase only

D = 208, 3 phase

H = 230, 1 phase only

F = Specify

Position #8: SPECIAL FEATURES

C = AC and DC arrestors

R = 115 VAC convenience outlet

D = DC arrestor

N = Powder coated cabinet (hot-dip galvanized standard on most models)

E = AC arrestor

O = Aluminum cabinet

F = Filter choke

T = Anodized aluminum cabinet

G = Communications filter

U = Anodized aluminum with clear coat

H = Meter switches

P = Additional voltage control link bar taps

I = Base mounting

S = Multiple rectifiers in one case (qty.)

J = Power On indicator light

Q = Other, specify ETL Certified

K = DC failure warning light

 

M = DC breaker (> 100 amps) or fuse

 

Available Products

Product NameQuoteSpecs
Air Cooled Standard Line Universal RectifiersPDF