Air Cooled Standard Line Rectifier
The "Standard Line" air cooled, cathodic protection rectifiers are recognized as industry leading in quality, workmanship and service life. Many years of field-proven service prove their superior design. Conservative equipment ratings, controlled manufacturing techniques, plus many extra features ensure long and trouble-free operation.
Typical cathodic protection applications for the air cooled rectifier line include pipelines, tank farms, storage fields, and other non-hazardous locations where continuous duty, DC power is required.
Standard Features:
· Weatherproof to NEMA 3R.
· Heavy duty 11-gauge hot dip galvanized cabinet with Stainless Steel Hardware.
· Stainless Steel, perforated screens.
· Front and side opening doors for easy maintenance.
· Heavy duty, draw-pull, stainless steel cabinet latch.
· Slide-out equipment racks, separate Transformer and Stack assemblies for units over 1200 watts.
· Heavy duty transformer with 15% over-design for reserve capacity.
· Minimum 18-step voltage control link bar taps.
· Quick-change, heavy-duty knobs for changing tap link bars.
· Minimum 5/16" diameter, soldered tap changing studs.
· 3/16" Grade XX, Phenolic front panel.
· Accessible front panel total precision shunt.
· Magnetic AC input circuit breaker.
· Magnetic AC Secondary Breakers on all units less than 100 amps (instead of fuses).
· Hoyt, separate analog, 2-1/2"round, volt and amp meters.
· Silicon diodes protected by surge suppressors and current limiting breakers <100 Amps or fuses.
· All electrical connection hardware is Nickel Plated and double-nut or soldered.
· Multi-strand, high temperature, insulated flexible wiring.
· Terminal block for AC input wires.
· Primary tap change panel for dual input voltages (Single Phase models only).
· Safety shield panel supplied on all units over 65 Volts DC.
Ordering Code / Model Number, Air Cooled Standard Line
| Position #1: MODEL |
| A = Air Cooled Line, Air Cooled |
| Position #2: TYPE | |
| S = Standard Rectifier (Manual taps) | P = Constant Potential (solid state) |
| C = Constant Current (Reactor style) | I = Constant Potential IR free (solid state) |
| D = Constant Current (Solid state) | M = Multiple Modes (Specify Modes Required) |
| E = Constant Voltage (Solid state) | V = Variac Control |
| Position #3: COOLING |
| A = Air Cooled |
| Position #4: STACK TYPE |
| I = Silicon (recommended); E = Selenium |
| Position #5: DC VOLTS |
| List Maximum DC Voltage Desired |
| Position #6: DC AMPS |
| List Maximum DC Amperage Desired |
| Position #7: AC INPUT | |
| AA = 115/230, 1 phase set for 115 vac | AB = 115/230, 1 phase set for 230 vac |
| BA = 230/460, 1 phase set for 230 vac | BB = 230/460, 1 phase set for 460 vac |
| CA = 230/460, 3 phase set for 230 vac | CB = 230/460, 3 phase set for 460 vac |
| EA = 115/460, 1 phase set for 115 vac | EB = 115/460, 1 phase set for 460 vac |
| G = 115, 1 phase only | D = 208, 3 phase |
| H = 230, 1 phase only | F = Specify |
| Position #8: SPECIAL FEATURES | |
| C = AC and DC arrestors | R = 115 VAC convenience outlet |
| D = DC arrestor | N = Powder coated cabinet (hot-dip galvanized standard on most models) |
| E = AC arrestor | O = Aluminum cabinet |
| F = Filter choke | T = Anodized aluminum cabinet |
| G = Communications filter | U = Anodized aluminum with clear coat |
| H = Meter switches | P = Additional voltage control link bar taps |
| I = Base mounting | S = Multiple rectifiers in one case (qty.) |
| J = Power On indicator light | Q = Other, specify ETL Certified |
| K = DC failure warning light | |
| M = DC breaker (> 100 amps) or fuse | |
Available Products
| Product Name | Quote | Specs |
|---|---|---|
| Air Cooled Standard Line Universal Rectifiers |
Don't see what you're looking for?
Contact our Corrosion Experts for help!
Contact Us