Stelth 2 Buried and Concrete Reference Electrodes
Stelth 2 Reference Electrodes (Underground and Concrete)
Stationary Reference Electrodes for Underground and Concrete
· Minimum 20 year service life.
· 28 square inches of sensing surface area gives 9 to 35 times more surface areas than other electrodes. This makes electrode positioning less critical to achieve accurate readings.
· Will not dry out in desert dry soil, a condition that renders other electrodes ineffective. Cyclical variations in soil conditions, ranging from hydrated to dehydrated, have adverse effect on the Stelth 2 electrode.
· Will not be destroyed by absolute dry soil conditions. It will only lie dormant until moisture returns. Electric Mud™ backfill will keep Stelth 2 in a moisture environment which keeps it continuously active.
· Electrode may be taken out of service for extended periods of time and reintroduced into the system without affecting electrode accuracy or ability to reactivate. Electrode will fire up in under 5 minutes.
· Technologically advanced chloride ion trap prevents chloride contamination of electrolyte.
· Available in three models: CuCuSO4, AgAgCL, ZnZnSO4.
· Color coding matches industry standards. Electrode and wire are both color coded for quick and easy remote identification of electrode chemistry.
· Fully compatible in a gelatin backfill environment such as Electric Mud™.
· Complete installation instructions included.
Stelth 2 Reference Electrodes (Underground and Concrete)
Stationary Reference Electrodes for Underground and Concrete
| SRE-007-CUY Copper-Copper Sulfate Electrode (Cu-CuSO4) for Underground and Concrete Service | SRE-008-SUB Silver-Silver Chloride Electrode (Ag-AgCL) for High Chloride Underground and Concrete Service | SRE-006-ZUR Zinc-Zinc Sulfate Electrode (Zn-ZnSO4) for Underground and Concrete Service | |
| Diameter | 1.5 in | 1.5 in | 1.5 in |
| Length | 6 in | 6 in | 6 in |
| Case Color | Yellow | Blue | Red |
| Case Material | Ceramic | Ceramic | Ceramic |
| Wire Size | 20 ft Standard (Contact Mesa for other lengths) | 20 ft Standard (Contact Mesa for other lengths) | 20 ft Standard (Contact Mesa for other lengths) |
| Wire Type | 14 RHH-RHW | 14 RHH-RHW | 14 RHH-RHW |
| Wire Color | Yellow | Blue | Red |
| Service Life | 20 years | 20 years | 20 years |
| Stability | 10 millivolts with 3 microamp load | 10 millivolts with 3 microamp load | 10 millivolts with 3 microamp load |
| Temperature Range | +32 to +135°F | +32 to +150°F | +32 to +135°F |
Available Products
| Product Name | Quote | Specs |
|---|---|---|
| Stelth 2 Buried and Concrete Reference Electrodes-Copper-Copper Sulfate Instructions | ||
| Stelth 2 Buried and Concrete Reference Electrodes-Silver-Silver Chloride Instructions | ||
| Stelth 2 Buried and Concrete Reference Electrodes-Zinc-Zinc Sulfate Instructions | ||
| Stelth 2 Specifications |
Don't see what you're looking for?
Contact our Corrosion Experts for help!
Contact Us